DC/DC Converter
TEN 50 Series, 50 Watt
•
Highest power density:
50 W in 1” x 2” x 0.4” package
•
•
Excellent efficiency up to 92 %
•
•
•
•
Output voltage adjustable
Operating temperature range
–40°C to +85°C
UL 62368-1 IEC 62368-1
Remote On/Off
I/O isolation 1500 VDC
3-year product warranty
The TEN 50 Series is a range of isolated high performance DC/DC converter
modules. Due to the very high efficiency of up to 92% and the use of highest
reliable components these 50 W converters come with a footprint of only 1.0” x
2.0”. The 12 models have a wide 2:1 input voltage range and a tight output
voltage regulation. They do not need a minimum load and a offer a high efficiency also at low load conditions. The output voltage is adjustable by external
resistor. Remote On/Off and protection against overload and short circuit are
standard features of these converters. Typical applications are in mobile equipment, instrumentation, distributed power architectures in communication and
industrial electronics and everywhere where space on the PCB is critical.
Models
Order Code
Input Voltage
Output Voltage
Output Current
Efficiency
Range
nom. (adjustable)
max.
typ.
TEN 50-1210
3.3 VDC (2.97 - 3.63 VDC)
10'000 mA
89 %
TEN 50-1211
5 VDC (4.5 - 5.5 VDC)
10'000 mA
90 %
12 VDC (10.8 - 13.2 VDC)
4'170 mA
91 %
15 VDC (13.5 - 16.5 VDC)
3'330 mA
91 %
9 - 18 VDC
(12 VDC nom.)
TEN 50-1212
TEN 50-1213
TEN 50-1215
24 VDC (21.6 - 28.8 VDC)
2'080 mA
91 %
TEN 50-2410
3.3 VDC (2.97 - 3.63 VDC)
10'000 mA
89 %
TEN 50-2411
18 - 36 VDC
(24 VDC nom.)
TEN 50-2412
5 VDC (4.5 - 5.5 VDC)
10'000 mA
92 %
12 VDC (10.8 - 13.2 VDC)
4'170 mA
92 %
15 VDC (13.5 - 16.5 VDC)
3'330 mA
92 %
TEN 50-2415
24 VDC (21.6 - 28.8 VDC)
2'080 mA
91 %
TEN 50-4810
3.3 VDC (2.97 - 3.63 VDC)
10'000 mA
89 %
TEN 50-4811
5 VDC (4.5 - 5.5 VDC)
10'000 mA
92 %
12 VDC (10.8 - 13.2 VDC)
4'170 mA
92 %
15 VDC (13.5 - 16.5 VDC)
3'330 mA
92 %
24 VDC (21.6 - 28.8 VDC)
2'080 mA
91 %
TEN 50-2413
36 - 75 VDC
(48 VDC nom.)
TEN 50-4812
TEN 50-4813
TEN 50-4815
Options
TEN-HS6
- Optional Heat Sink: www.tracopower.com/products/ten-hs6.pdf
www.tracopower.com
September 20, 2023
Page 1 / 5
TEN 50 Series, 50 Watt
Input Specifications
Input Current
12 Vin models: 85 mA typ. (3.3 Vout model)
110 mA typ. (5 Vout model)
160 mA typ. (12 Vout model)
160 mA typ. (15 Vout model)
250 mA typ. (24 Vout model)
24 Vin models: 50 mA typ. (3.3 Vout model)
70 mA typ. (5 Vout model)
85 mA typ. (12 Vout model)
85 mA typ. (15 Vout model)
110 mA typ. (24 Vout model)
48 Vin models: 35 mA typ. (3.3 Vout model)
45 mA typ. (5 Vout model)
50 mA typ. (12 Vout model)
50 mA typ. (15 Vout model)
60 mA typ. (24 Vout model)
12 Vin models: 3'090 mA typ. (3.3 Vout model)
4'630 mA typ. (5 Vout model)
4'580 mA typ. (12 Vout model)
4'580 mA typ. (15 Vout model)
4'570 mA typ. (24 Vout model)
24 Vin models: 1'550 mA typ. (3.3 Vout model)
2'260 mA typ. (5 Vout model)
2'260 mA typ. (12 Vout model)
2'260 mA typ. (15 Vout model)
2'290 mA typ. (24 Vout model)
48 Vin models: 770 mA typ. (3.3 Vout model)
1'130 mA typ. (5 Vout model)
1'130 mA typ. (12 Vout model)
1'130 mA typ. (15 Vout model)
1'150 mA typ. (24 Vout model)
12 Vin models: 25 VDC max. (100 ms max.)
24 Vin models: 50 VDC max. (100 ms max.)
48 Vin models: 100 VDC max. (100 ms max.)
12 Vin models: 8.3 VDC typ.
24 Vin models: 16.5 VDC typ.
48 Vin models: 33 VDC typ.
12 Vin models: 50 mAp-p typ.
24 Vin models: 40 mAp-p typ.
48 Vin models: 30 mAp-p typ.
12 Vin models: 10'000 mA (slow blow)
24 Vin models: 5'000 mA (slow blow)
48 Vin models: 2'500 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal LC-Type
- At no load
- At full load
Surge Voltage
Under Voltage Lockout
Reflected Ripple Current
Recommended Input Fuse
Input Filter
Output Specifications
Output Voltage Adjustment
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
–10% to +20% (24 Vout models)
±10% (other single models)
(By external trim resistor)
See application note: www.tracopower.com/overview/ten50
Output power must not exceed rated power!
±1% max.
0.5% max.
0.5% max.
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 2 / 5
TEN 50 Series, 50 Watt
Ripple and Noise
(20 MHz Bandwidth)
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
Capacitive Load
Minimum Load
Temperature Coefficient
Start-up Time
Short Circuit Protection
Output Current Limitation
Transient Response
- Response Deviation
- Response Time
100 mVp-p max. (w/ 1 µF MLCC || 10 µF TC)
100 mVp-p max. (w/ 1 µF MLCC || 10 µF TC)
150 mVp-p max. (w/ 1 µF MLCC || 10 µF TC)
150 mVp-p max. (w/ 1 µF MLCC || 10 µF TC)
150 mVp-p max. (w/ 1 µF MLCC || 10 µF TC)
25'800 µF max.
17'000 µF max.
2'900 µF max.
1'900 µF max.
750 µF max.
Not required
±0.02 %/K max.
30 ms max. (Power On)
30 ms max. (Remote On)
Continuous, Automatic recovery
150% typ. of Iout max.
3% typ. / 5% max. (75% to 100% Load Step)
250 µs typ. (75% to 100% Load Step)
Safety Specifications
Safety Standards
CSA-C22.2, No. 60950-1
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
www.tracopower.com/overview/ten50
PD 3
Not mains connected
- IT / Multimedia Equipment
- Certification Documents
Pollution Degree
Over Voltage Category
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
External filter proposal:
EMS Immunity
- Electrostatic Discharge
Air:
Contact:
- RF Electromagnetic Field
- EFT (Burst) / Surge
External filter proposal:
- Conducted RF Disturbances
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
FCC Part 15 class A (with external filter)
EN 55032 class A (with external filter)
FCC Part 15 class A (with external filter)
www.tracopower.com/overview/ten50
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
www.tracopower.com/overview/ten50
EN 61000-4-6, 10 Vrms, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
Power Derating
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
95% max. (non condensing)
–40°C to +85°C
+105°C max.
–50°C to +125°C
Depending on model
See application note: www.tracopower.com/overview/ten50
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 3 / 5
TEN 50 Series, 50 Watt
Over Temperature
Protection Switch Off
Cooling System
Remote Control
110°C typ.
- Protection Mode
- Voltage Controlled Remote
- Off Idle Input Current
- Remote Pin Input Current
Altitude During Operation
Switching Frequency
Insulation System
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Washing Process
- Input to Output, 60 s
- Input to Output, 1 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
Housing Material
Base Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Thermal Impedance
Natural convection (20 LFM)
On: 3.5 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
2.5 mA typ.
-0.5 to 0.5 mA
6'000 m max.
285 kHz typ. (PWM) (24 Vout models)
320 kHz typ. (PWM) (other models)
Functional Insulation
1'500 VDC
1'800 VDC
1'000 MΩ min.
2'200 pF max.
220'000 h (MIL-HDBK-217F, ground benign)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
Alu alloy, black anodized coating
Non-conductive FR4 (UL 94 V-0 rated)
Epoxy (UL 94 V-0 rated)
Copper Alloy (C6801)
Nickel (2.5 µm min.)
Gold (75 - 125 nm), glossy
Metal Case
PCB Mount
THD (Through-Hole Device)
2" x 1"
Lead-Free Wave Soldering
260°C / 10 s max.
30 g
12 K/W typ.
10 K/W typ. (with Heat Sink)
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a, 7c-I
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
5a2a420b-ee13-4969-bf97-1218c3094530
- Case to Ambient
Environmental Compliance - REACH Declaration
- RoHS Declaration
- SCIP Reference Number
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/ten50
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 4 / 5
TEN 50 Series, 50 Watt
2.54
5
3
3.6 (0.14)
1.85 (0.073)
(0.400)
Bottom view
Pinout
25.4 (1.00)
(0.400)
10.16
2
(0.400)
4
1
10.16 10.16
5.08
(0.200)
50.8 (2.00)
(0.100)
Outline Dimensions
6
11.0
(0.43)
5.5
(0.22)
45.72 (1.800)
Pin
Single
1
+Vin (Vcc)
2
–Vin (GND)
3
Remote On/Off
4
+Vout
5
–Vout
6
Trim
Ø1.0 (Ø0.04)
Dimensions in mm (inch)
Tolerances: x.x ±0.25 (x.xx ±0.01)
x.xx ±0.13 (x.xxx ±0.005)
Pin diameter tolerances: x.x ±0.05 (x.xx ±0.002)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. September 20, 2023
Page 5 / 5
很抱歉,暂时无法提供与“TEN 50-4815”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+827.765641+98.97330
- 10+723.8846810+86.55259
- 25+699.9878025+83.69531
- 50+682.4338750+81.59645
- 100+665.31802100+79.54996
- 250+592.35397250+70.82588